Alfil 45

European Chamber Practicable

Characterized by a wide range of profiles that allow all types of construction solutions. Its strong position in the market over many years has enabled the profiles to gradually adapt to new aesthetic trends, and it is now available in round, elliptical, or straight finishes, adapting in each case to customer preferences. It is a robust series, easy to assemble, appealing to those seeking good quality aluminum at a balanced price.

GENERAL INFORMATION

  • Base frame dimensions: 45 mm, sash: 52 mm
  • Maximum glass thickness: 35 mm
  • General profile thickness: 1.4 mm

TECHNICAL FEATURES

 

Tilt-and-turn window with European groove, frame of 45 mm and sash of 52 mm. The large variety of profiles available in the series allows for multiple technical solutions (tilt-and-turn, pivot, parallel tilt, coupling with sliding systems, etc.).

Performance results from laboratory tests are as follows:

  • Air permeability: 4
  • Water tightness: 9A
  • Wind load resistance: C4
  • Acoustic attenuation: 33 dB

The frame’s thermal transmittance is 6.1 W/m²K. According to the CTE (Technical Building Code), which requires minimum thermal performance depending on the geographical location, this series is especially suitable for climate zones A and B, although with sufficiently insulating glass it could also be used in zones C, D, and E.

The frame profiles feature a clipping system that allows easy positioning of auxiliary profiles such as joint covers, drip edges, or frame unions.

Innaltech supplies the complete range of accessories for this system. All our systems are computer-integrated for material breakdown, cutting optimization, manufacturing sheets, and CE marking labels. Additionally, cutting and machining automation at machining centers is possible. The software is available in Spanish, Catalan, and French.

Openings

Essays

AEV Tests

Window Test Report Air Water Wind
1400 x 1500 mm, 2 tilt-and-turn sashes, glass 4/14/4 09/100329-1682 (APPLUS) 4 9A C4
1600 x 2100 mm, 2 tilt-and-turn sashes, glass 4/14/4 10/101179-161 (APPLUS) 4 9A C2
1600 x 2100 mm, 2 tilt-and-turn sashes + monobloc box, glass 4/14/4 10/10179-1376 (APPLUS) 4 7A C1

 

Acoustic Tests for Windows

Window Test Report Result (dB)
1400 x 1500 mm, 2 tilt-and-turn sashes, glass 4/14/4 10/101124-36 (APPLUS) 33
1400 x 1500 mm, 2 tilt-and-turn sashes, glass 3+3/10/6 10/101124-35 (APPLUS) 36

Thermal Tests for Frame

Frame Test Report Result (W/m2K)
Perimeter Joint 25130-1 (CIDEMCO) 6,1
Central Joint 25130-2 (CIDEMCO) 6,1

 

Thermal Tests for Windows According to

Window Result (W/m2K) 4/10/4 (Ug=2,8) Result (W/m2K) 4/10/4 BE* (Ug=1,5) Result (W/m2K) 4/16 Ar/4 BE** (Ug = 1,1)
1 sash window 820 x 2100 mm 3,80 2,89 2,61
2 sash window 1400 x 1500 mm 3,94 3,08 2,82
2 sash window 1600 x 2100 mm 3,75 2,82 2,54
*BE = Low Emissivity
** Thermal result obtained by placing the Foam Isolation System on the sash

Measures

Window measurements covered by the test
Window measurements not recommended/not feasible
  • Air permeability and watertightness tests covered
  • Air permeability, watertightness, and wind load resistance tests covered
  • Measures not recommended
  • Measures not feasible
    * Maximum recommended weight with the most unfavorable tilt-and-turn hardware
Our site uses cookies to collect information about your device and browsing activity. We use this data to improve the site, ensure security and deliver personalized content. You can manage your cookie preferences by clicking here.
Accept cookies Configure Decline cookies
Basic cookie information
This website uses cookies and/or similar technologies that store and retrieve information when you browse. In general, these technologies can serve very different purposes, such as, for example, recognizing you as a user, obtaining information about your browsing habits or personalizing the way in which the content is displayed. The specific uses we make of these technologies are described below. By default, all cookies are disabled, except for technical ones, which are necessary for the website to function. If you wish to obtain more information or exercise your data protection rights, you can consult our Seguimiento".
Accept cookies Configure
Technical cookies needed Always active
Technical cookies are strictly necessary for our website to work and for you to navigate through it. These types of cookies are those that, for example, allow us to identify you, give you access to certain restricted parts of the page if necessary, or remember different options or services already selected by you, such as your privacy preferences. Therefore, they are activated by default, your authorization is not necessary.rnThrough the configuration of your browser, you can block or alert the presence of this type of cookies, although such blocking will affect the proper functioning of the different functionalities of our website.
Cookies de análisis
Las cookies de análisis son las utilizadas para llevar a cabo el análisis anónimo del comportamiento de los usuarios de la web y que permiten medir la actividad del usuario y elaborar perfiles de navegación con el fin objetivo de mejorar los sitios web.
Confirm preferences
Title
Popupcontent
Contacta con nosotros
Aceptar