European Chamber Practicable with RPT

It is a cold series (without thermal break), designed to achieve good watertightness performance at a reduced cost and with quick and easy assembly. It is a versatile series that adapts to various types of closures and allows different aesthetic finishes according to the final customer’s preferences. The frame profiles feature a clipping system that enables easy placement of auxiliary profiles such as trim covers, drip edges, or frame joints.

General information

  • Base frame dimensions: 40 mm
  • Sash (leaf) dimensions: 47 mm
  • Maximum glass thickness: 30 mm
  • General profile thickness: 1.4 mm

General features

  • Casement window with European groove, frame 40 mm and sash 47 mm.
  • The large number of profiles available in the series allows multiple technical solutions (casement, tilt-and-turn, pivot, tilt-slide, coupling with sliding systems, etc.).
  • Laboratory test results:
  • Air permeability: Class 4
  • Watertightness: E1350
  • Wind load resistance: Class C4
  • Acoustic attenuation: 31 dB
  • The thermal transmittance of the frame is 6.0 W/m²K. According to the Spanish
  • Technical Building Code (CTE), which requires minimum thermal performance based on geographic location, this series is especially suitable for climate zones A and B, although with sufficiently insulating glass it could also be installed in zones C, D, and E.
  • Frame profiles include a clipping system that allows easy positioning of auxiliary profiles such as trim covers, drip edges, or frame joints.

Innaltech supplies the complete range of accessories for this system. All our systems are digitally integrated for material breakdown, cutting optimization, manufacturing sheets, and CE marking labels. Additionally, it is possible to automate cutting and machining in CNC machining centers. The software is available in Spanish, Catalan, and French.

Openings

Essays Practic 40

Tests results AEV

Window Description Test Report Air Water Wind
1400 x 1500 mm 2 leaf tilt-and-turn, glass 4/14/4 09/100329-1683 (APPLUS) 4 4 E1350 C4
1600 x 2100 mm 2 leaf tilt-and-turn, glass 4/14/4 10/101179-163 (APPLUS) 4 7A C2
1600 x 2100 mm 2 leaf tilt-and-turn + monobloc box, glass 4/14/4 10/10179-1633 (APPLUS) 4 8A C1

Acoustic tests – Windows

Window Description Test report Result (dB)
1400 x 1500 mm 2 leaf tilt-and-turn, glass 4/14/4 10/101124-34 (APPLUS) 31
1400 x 1500 mm 2 leaf tilt-and-turn, laminated glass 3+3/10/6 10/101124-33 (APPLUS) 34

Thermal tests – Framer

Frame section Test report Result (W/m2K)
Perimeter Joint 25130-3 (CIDEMCO) 6,0
Central Joint 25130-4 (CIDEMCO) 6,0

Thermal tests – Window accorsding to CTE

Window Description Result (W/m2K) 4/10/4 (Ug=2,8) Result (W/m2K) 4/10/4 BE* (Ug=1,9) Result (W/m2K) 4/16 Ar/4 BE** (Ug = 1,1)
1-leaf window 820 x 2100 mm 3,77 2,85 2,59
2-leaf window 1400 x 1500 mm 3,90 3,03 2,76
2-leaf window 1600 x 2100 mm 3,72 2,78 2,49
*Low Emissivity Glass
**Thermal result obtained by applying Foam Isolation System on the sash

Measures

Window dimensions covered by the test
Measures not recommended/not feasible
  • Air permeability and watertightness tests covered
  • Air permeability, watertightness, and wind load resistance tests covered
  • Measures not recommended
  • Measures not feasible

* Maximum recommended weight with the most unfavorable tilt-and-turn hardware

Our site uses cookies to collect information about your device and browsing activity. We use this data to improve the site, ensure security and deliver personalized content. You can manage your cookie preferences by clicking here.
Accept cookies Configure Decline cookies
Basic cookie information
This website uses cookies and/or similar technologies that store and retrieve information when you browse. In general, these technologies can serve very different purposes, such as, for example, recognizing you as a user, obtaining information about your browsing habits or personalizing the way in which the content is displayed. The specific uses we make of these technologies are described below. By default, all cookies are disabled, except for technical ones, which are necessary for the website to function. If you wish to obtain more information or exercise your data protection rights, you can consult our Seguimiento".
Accept cookies Configure
Technical cookies needed Always active
Technical cookies are strictly necessary for our website to work and for you to navigate through it. These types of cookies are those that, for example, allow us to identify you, give you access to certain restricted parts of the page if necessary, or remember different options or services already selected by you, such as your privacy preferences. Therefore, they are activated by default, your authorization is not necessary.rnThrough the configuration of your browser, you can block or alert the presence of this type of cookies, although such blocking will affect the proper functioning of the different functionalities of our website.
Cookies de análisis
Las cookies de análisis son las utilizadas para llevar a cabo el análisis anónimo del comportamiento de los usuarios de la web y que permiten medir la actividad del usuario y elaborar perfiles de navegación con el fin objetivo de mejorar los sitios web.
Confirm preferences
Title
Popupcontent
Contacta con nosotros
Aceptar