Practic 54 RPT

European chamber casement window, or 16 mm channel, with thermal break (RPT)

The modification of the base width by replacing the 14.8 mm polyamides with 24 mm ones has resulted in a significant increase in thermal and acoustic insulation. The central gasket was also modified to adapt to the new configuration, and the consequent increase in the drainage chamber has allowed achieving first-class watertightness values. This is a balanced system, optimal for areas with significant temperature fluctuations.

General information

  • Base frame dimensions: 54 mm
  • Sash dimensions: 61 mm
  • Maximum glass thickness: 45 mm
  • General profile thickness: 1.4 mm

 

Technical features

Casement window with European channel with thermal break (RPT) with a 54 mm frame and 61 mm sash.

The performance results from the test bench are as follows:

  • Air permeability: 4
  • Watertightness: E1050
  • Wind load resistance: C5
  • Acoustic attenuation: 34 dB

 

The frame thermal transmittance is 3.0 W/m²K. According to the CTE (Technical Building Code), which requires minimum thermal performance depending on geographic location, this series is suitable for all climatic zones A and B; however, for zones D and E, the use of insulating glass is recommended.

The frame profiles include a clipping system that allows easy positioning of auxiliary profiles such as cover trims, drip edges, or frame joints.

Innaltech supplies the full range of accessories for this system. All our systems are fully integrated digitally regarding material breakdown, cutting optimization, manufacturing sheets, and CE marking labels. It is also possible to automate cutting and machining in the machining center. The software is available in Spanish, Catalan, and French.

Openings

Essays

Performed AEV Tests

Window Test Report Air Water Wind
820 x 2100 mm 1-leaf tilt & turn, glass 4/16/4 10/101179-1632 (APPLUS) 4 E1050 C5
1400 x 1500 mm 2-leaf tilt & turn, glass 4/16/4 09/32300724 (APPLUS) 4 E1200 C4
1600 x 2100 mm -leaf tilt & turn + monobloc box, glass 4/16/4 10/101179-1374 (APPLUS) 4 E900 C1
2900 x 2300 mm 4-leaf casement, glass 4/16/4 10/101179-2717 (APPLUS) 4 6A C2
1600 x 2100 mm 2-leaf tilt & turn, hardware C16, glass 4/16/4 Internal 4 E900 C2

 

Acoustic Tests on Windows

Window Test Report Result (dB)
1400 x 1500 mm 2-leaf tilt & turn, glass 4/16/4 10/101124-42 (APPLUS) 34
1400 x 1500 mm 2-leaf tilt & turn, glass 3+3/16/6 10/101124-41 (APPLUS) 37

 

Thermal Tests on Frame

Frame Part Test Report Result (W/m2K)
Perimeter joint 25130-20 (CIDEMCO) 3,0
Central joint 25130-21 (CIDEMCO) 3,0

 

Thermal Tests on Frame with Foam Isolation System

Frame Part Test report Result (W/m2K)
Perimeter joint Internal 2,5
Central joint Internal 2,5

 

Thermal Tests on Windows According to CTE

Window Result (W/m2K)
4/14/4 (Ug=2,8)
Result (W/m2K)
4/14/4 BE* (Ug=1,5)
Result (W/m2K)
4/16 Ar/4 BE**
(Ug = 1,1)
Result (W/m2K)
4/14 Ar/4/14 Ar/4 BE**
(Ug = 0,8)
Result (W/m2K)
4/16 Ar/4/16 Ar/4 BE**
(Ug = 0,6)
1-leaf window 820 x 2100 mm 2,79 1,95 1,52 1,30 1,16
2-leaf window 1400 x 1500 mm 2,80 2,00 1,56 1,36 1,23
2-leaf window 1600 x 2100 mm 2,78 1,92 1,49 1,27 1,13
* Low Emissivity
** Thermal results obtained by installing the Foam Isolation System in the sash

Measures

Window dimensions covered by the test
Measures not recommended/not feasible
  • Air permeability and watertightness tests covered
  • Air permeability, watertightness, and wind load resistance tests covered
  • Measures not recommended
  • Measures not feasible

* Maximum recommended weight with the most unfavorable tilt-and-turn hardware

Our site uses cookies to collect information about your device and browsing activity. We use this data to improve the site, ensure security and deliver personalized content. You can manage your cookie preferences by clicking here.
Accept cookies Configure Decline cookies
Basic cookie information
This website uses cookies and/or similar technologies that store and retrieve information when you browse. In general, these technologies can serve very different purposes, such as, for example, recognizing you as a user, obtaining information about your browsing habits or personalizing the way in which the content is displayed. The specific uses we make of these technologies are described below. By default, all cookies are disabled, except for technical ones, which are necessary for the website to function. If you wish to obtain more information or exercise your data protection rights, you can consult our Seguimiento".
Accept cookies Configure
Technical cookies needed Always active
Technical cookies are strictly necessary for our website to work and for you to navigate through it. These types of cookies are those that, for example, allow us to identify you, give you access to certain restricted parts of the page if necessary, or remember different options or services already selected by you, such as your privacy preferences. Therefore, they are activated by default, your authorization is not necessary.rnThrough the configuration of your browser, you can block or alert the presence of this type of cookies, although such blocking will affect the proper functioning of the different functionalities of our website.
Cookies de análisis
Las cookies de análisis son las utilizadas para llevar a cabo el análisis anónimo del comportamiento de los usuarios de la web y que permiten medir la actividad del usuario y elaborar perfiles de navegación con el fin objetivo de mejorar los sitios web.
Confirm preferences
Title
Popupcontent
Contacta con nosotros
Aceptar