Practicable with RPT

PRACTIC CONCEALED LEAF 70 RPT

Recessed casement window with RPT, available in European or C16 channel

This system offers a greater glazed surface compared to traditional systems. It also gives the enclosure a uniform and functional aesthetic, since from the outside it is impossible to distinguish between the operable and fixed sashes. For these reasons, architects prefer this type of enclosure over conventional frame-and-visible-sash systems.

A minimalist system, it features a visible frame width of just 58.8 mm. This particular feature makes it one of the casement systems with the slimmest sections and, therefore, the largest glazed surface area on the market.

Thermal transmittance values are very low thanks to the use of 34 mm polyamides in the frame and a mixed plastic-aluminium sash, in addition to the reduced profile section which increases the impact of the glass. The new HT70·1290 sash allows for glazing up to 50 mm, making the system ideal for TRIPLEX glass installation. Exceptional sealing levels are achieved thanks to the triple gasket system.

GENERAL INFORMATION

  • Base dimensions – frame: 70 mm, sash: 71 mm
  • Maximum glass thickness: 50 mm
  • General profile thickness: 1.6 mm

 

TECHNICAL FEATURES

 

European channel casement system with thermal break (RPT – Thermal Bridge Break).

Test performance results:

  • Air permeability: Class 4
  • Water tightness: E1500
  • Wind load resistance: C5
  • Acoustic insulation: 46 dB
  • Frame thermal transmittance: 2.3 W/m²K

According to the CTE (Spanish Technical Building Code), which sets minimum thermal performance requirements based on geographic location, this series is suitable for a wide range of climates. Furthermore, the increased glazed area made possible by the slim profiles allows for even lower overall thermal transmittance values when using adequately insulating glass.

Innaltech provides the complete range of accessories for this system. All our systems are fully integrated digitally, including material breakdowns, cutting optimization, manufacturing sheets, and CE marking labels. Additionally, cutting and machining can be automated using a CNC machining center. The software is available in Spanish, Catalan, and French.

 

Openings

Tests

AEV Tests Performed

Window Test Report Air Water Wind
950 x 1480 mm, 1 tilt-and-turn sash, 4/16/4 glazing 12/5331-1150 (APPLUS) 4 E1500 C5
1235 x 1470 mm, 2 tilt-and-turn sashes, 4/16/4 glazing 17/14382-1097 M1(APPLUS) 4 9A C5

 

Acoustic Tests – Window

Window Test Report Result (dB)
1400 x 1500 mm, 2 tilt-and-turn sashes, 4/16/4 glazing 10/101124-54 (APPLUS) 46

 

Thermal Tests – Frame

Frame Test Report Result (W/m2K)
Perimeter junction 12_04010-6 (CIDEMCO) 2,3
Central junction Internal 2,3

 

Thermal Tests – Frame with Foam Isolation System

Frame Test Report Result (W/m2K)
Perimeter junction Interno 2,0
Central junction Interno 2,0

 

Thermal Tests – Window According to CTE

Window Result (W/m2K)
4/14/4 (Ug=2,8)
Result (W/m2K)
4/14/4 BE* (Ug=1,5)
Result (W/m2K)
4/16 Ar/4 BE** (Ug = 1,1)
Result (W/m2K)
4/16 Ar/4/16 Ar/4 BE** (Ug = 0,7)
1 sash – 820 x 2100 mm 2,71 1,69 1,34 0,88
2 sashes – 1400 x 1500 mm 2,72 1,71 1,36 0,99
2 sashes – 1600 x 2100 mm 2,73 1,68 1,32 0,94
* Low Emissivity
** Thermal performance was obtained by applying the Foam Isolation System to the sash

Measures

Window dimensions covered by the test
Measures not recommended / not feasible
  • Air permeability and watertightness tests covered
  • Air permeability, watertightness, and wind load resistance tests covered
  • Measures not recommended
  • Measures not feasible

* Maximum recommended weight with the most unfavorable tilt-and-turn hardware

Our site uses cookies to collect information about your device and browsing activity. We use this data to improve the site, ensure security and deliver personalized content. You can manage your cookie preferences by clicking here.
Accept cookies Configure Decline cookies
Basic cookie information
This website uses cookies and/or similar technologies that store and retrieve information when you browse. In general, these technologies can serve very different purposes, such as, for example, recognizing you as a user, obtaining information about your browsing habits or personalizing the way in which the content is displayed. The specific uses we make of these technologies are described below. By default, all cookies are disabled, except for technical ones, which are necessary for the website to function. If you wish to obtain more information or exercise your data protection rights, you can consult our Seguimiento".
Accept cookies Configure
Technical cookies needed Always active
Technical cookies are strictly necessary for our website to work and for you to navigate through it. These types of cookies are those that, for example, allow us to identify you, give you access to certain restricted parts of the page if necessary, or remember different options or services already selected by you, such as your privacy preferences. Therefore, they are activated by default, your authorization is not necessary.rnThrough the configuration of your browser, you can block or alert the presence of this type of cookies, although such blocking will affect the proper functioning of the different functionalities of our website.
Cookies de análisis
Las cookies de análisis son las utilizadas para llevar a cabo el análisis anónimo del comportamiento de los usuarios de la web y que permiten medir la actividad del usuario y elaborar perfiles de navegación con el fin objetivo de mejorar los sitios web.
Confirm preferences
Title
Popupcontent
Contacta con nosotros
Aceptar